• DocumentCode
    910379
  • Title

    Rotor winding short detection

  • Author

    Wood, J.W. ; Hindmarch, R.T.

  • Author_Institution
    NEI Parsons Ltd., Research and Development Laboratories, Newcastle upon Tyne, UK
  • Volume
    133
  • Issue
    3
  • fYear
    1986
  • fDate
    5/1/1986 12:00:00 AM
  • Firstpage
    181
  • Lastpage
    189
  • Abstract
    The paper presents a review of four techniques which are used for detecting, and in some instances locating, short-circuited turns in the rotors of large turbogenerators. The information is supplemented by experience with some of the techniques gained in a manufacturing establishment. The four techniques described are airgap search coil, recurrent surge oscillograph (RSO), circulating stator current, and rotor shaft current.
  • Keywords
    electric current measurement; fault location; machine testing; rotors; short-circuit currents; turbogenerators; airgap search coil; circulating stator current; recurrent surge oscillograph; rotor shaft current; rotor windings; short circuit detection; turbogenerators;
  • fLanguage
    English
  • Journal_Title
    Electric Power Applications, IEE Proceedings B
  • Publisher
    iet
  • ISSN
    0143-7038
  • Type

    jour

  • DOI
    10.1049/ip-b:19860025
  • Filename
    4644164