DocumentCode :
910384
Title :
Comments on "An S-Band Radiometer Design with High Absolute Precision" [Letters]
Author :
Keen, N.J.
Volume :
23
Issue :
5
fYear :
1975
fDate :
5/1/1975 12:00:00 AM
Firstpage :
456
Lastpage :
457
Abstract :
In the above paper, a highly stable noise-balancing radiometer at 2.7 GHz for satellite applications, with a claimed absolute measurement precision of 0.1 K, is reported. The purpose of this letter is to indicate a source of calibration error which can be seriously underestimated.
Keywords :
Antenna feeds; Calibration; Capacitance; Microstrip; Microwave radiometry; Noise level; Polarization; Receiving antennas; Reflection; Reflector antennas;