DocumentCode :
910404
Title :
Electrical machine core imperfection detection
Author :
Rickson, C.
Author_Institution :
Adwel Industries Ltd., Ruislip, UK
Volume :
133
Issue :
3
fYear :
1986
fDate :
5/1/1986 12:00:00 AM
Firstpage :
190
Lastpage :
195
Abstract :
The paper describes the development of a core imperfection monitoring and detection system which eliminates the need for a high-voltage high-current excitation winding. The system is based on an electromagnetic testing technique. The paper reports a number of tests conducted in the United Kingdom and USA and gives comparisons of results made with the conventional ring flux test method and the new method. Accuracy of fault location and ease of implementation are discussed.
Keywords :
electric machines; fault location; machine testing; monitoring; stators; core imperfection monitoring; electromagnetic testing; fault location; generators; motors; ring flux test; stator cores;
fLanguage :
English
Journal_Title :
Electric Power Applications, IEE Proceedings B
Publisher :
iet
ISSN :
0143-7038
Type :
jour
DOI :
10.1049/ip-b:19860026
Filename :
4644167
Link To Document :
بازگشت