• DocumentCode
    911550
  • Title

    Output impedance considerations for switching regulators with current-injected control

  • Author

    Schoneman, George K. ; Mitchell, Daniel M.

  • Author_Institution
    Collins Defense Commun., Cedar Rapids, IA, USA
  • Volume
    4
  • Issue
    1
  • fYear
    1989
  • fDate
    1/1/1989 12:00:00 AM
  • Firstpage
    25
  • Lastpage
    35
  • Abstract
    The output impedance of current-injection-controlled (CIC) buck regulators can be significantly reduced by deriving the current control signal from the output capacitor instead of the inductor. This technique is shown to be mathematically equivalent to CIC with load-current feedforward. Performance comparisons with normally implemented CIC and voltage control are given
  • Keywords
    electric current control; electric impedance; switching circuits; voltage regulators; current control signal; current-injected control; load-current feedforward; output capacitor; output impedance; switching regulators; Capacitors; Current control; Equations; Frequency; Impedance; Inductors; Regulators; Topology; Vectors; Voltage control;
  • fLanguage
    English
  • Journal_Title
    Power Electronics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-8993
  • Type

    jour

  • DOI
    10.1109/63.21870
  • Filename
    21870