Title :
New Method of Gamma Dose-Rate Measurement Using Energy-Sensitive Counters
Author :
Kopp, M.K. ; Valentine, K.H. ; Williams, J.A. ; Bamberger, R.H.
Author_Institution :
Oak Ridge National Laboratory, P.O. Box X, Oak Ridge, TN 37831-6008 USA
Abstract :
A new concept of charge quantization and pulse-rate measurement was developed to monitor low-level gamma dose rates using energy-sensitive, air-equivalent counters. Applying this concept, the charge from each detected photon is quantized by level-sensitive comparators so that the resulting total output pulse rate is proportional to dose rate. The concept was tested with a proportional counter and a solid-state detector for wide-range dose-rate monitoring applications. The prototypic monitors cover a dose-rate range from background radiation levels (10 ¿R/h) to 10 R/h.
Keywords :
Charge measurement; Counting circuits; Current measurement; Energy measurement; Monitoring; Pulse measurements; Quantization; Radiation detectors; Solid state circuits; Testing;
Journal_Title :
Nuclear Science, IEEE Transactions on
DOI :
10.1109/TNS.1987.4337418