DocumentCode
912836
Title
New method of analysis and performance prediction for thyristor voltage-controlled RL loads
Author
Hamed, S.A. ; Chalmers, B.J.
Author_Institution
University of Jordan, Department of Electrical Engineering, Amman, Jordan
Volume
134
Issue
6
fYear
1987
fDate
11/1/1987 12:00:00 AM
Firstpage
339
Lastpage
347
Abstract
A new method of analysis of thyristor voltage-controlled RL loads is described, based upon power considerations. Use of the thyristor conduction angle as the independent variable is shown to yield the most direct and efficient computation of performance. Purely resistive and inductive loads are covered as special cases. The 3-phase circuit with antiparallel thyristors is considered in detail as an example and its general characteristics are given.
Keywords
thyristor applications; voltage control; 3-phase circuit; antiparallel thyristors; inductive loads; performance prediction; resistive loads; thyristor conduction angle; thyristor voltage-controlled RL loads;
fLanguage
English
Journal_Title
Electric Power Applications, IEE Proceedings B
Publisher
iet
ISSN
0143-7038
Type
jour
DOI
10.1049/ip-b:19870051