• DocumentCode
    913121
  • Title

    Ionizing Radiation Dose Distribution Produced inside a Canonical Cavity by Direct e-Beam Excitation

  • Author

    Fleetwood, R. ; Kerris, K. ; Merkel, G. ; Roberts, H. ; Smith, M.

  • Author_Institution
    Harry Diamond Laboratories US Army LABCOM 2800 Powder Mill Road Adelphi, MD 20783-1197
  • Volume
    34
  • Issue
    6
  • fYear
    1987
  • Firstpage
    1521
  • Lastpage
    1527
  • Abstract
    Reliable dosimetry methods have been developed to map relativistic electrons that have been injected into a generic cavity. These measuring techniques are: (1) thermoluminescent dosimeters (TLDs) combined with photodiodes yielding dose rate; (2) TLD telescopes yielding electron angular distributions; and (3) TLD mosaic arrays yielding rough energy spectra. Total dose, dose rate, electron angular distribution and current density measurements have been obtained during electromagnetic excitation of a canonical cavity with diffuse electron beam (e-beam) bombardment. A theoretical interpretation of the dose rate and electron current density measurements is presented.
  • Keywords
    Current density; Current measurement; Density measurement; Dosimetry; Electromagnetic measurements; Electron beams; Energy measurement; Ionizing radiation; Photodiodes; Telescopes;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1987.4337509
  • Filename
    4337509