• DocumentCode
    913656
  • Title

    The SEU and Total Dose Response of the INMOS Transputer

  • Author

    Thomlinson, J. ; Adams, Leon ; Harboe-Sorensen, R.

  • Author_Institution
    ESA-ESTEC, Noordwijk, The Netherlands
  • Volume
    34
  • Issue
    6
  • fYear
    1987
  • Firstpage
    1803
  • Lastpage
    1807
  • Abstract
    The INMOS Transputer is a unique 32-bit processor intended for parallel processing applications. Initial application evaluation by the European Space Agency (ESA) has shown the device to be of major interest in the areas of image processing and fault tolerance. An SEU and total dose evaluation program has been carried out using Californium-252, a Tandem Accelerator, Cobalt-60 and 150 keV X-rays. The SEU Threshold was found to be about 3 (MeV.cm2/mg) and the limiting Cross-Section 2x10-6 cm2 per bit at an LET of 43 (MeV.cm2/mg). The total dose hardness was found to be in the range of 35-50 Krads and to be dose-rate sensitive.
  • Keywords
    Extraterrestrial measurements; Fault tolerance; Manufacturing; Microprocessors; Performance evaluation; Random access memory; Read-write memory; Single event upset; Software testing; System testing;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1987.4337559
  • Filename
    4337559