DocumentCode :
913656
Title :
The SEU and Total Dose Response of the INMOS Transputer
Author :
Thomlinson, J. ; Adams, Leon ; Harboe-Sorensen, R.
Author_Institution :
ESA-ESTEC, Noordwijk, The Netherlands
Volume :
34
Issue :
6
fYear :
1987
Firstpage :
1803
Lastpage :
1807
Abstract :
The INMOS Transputer is a unique 32-bit processor intended for parallel processing applications. Initial application evaluation by the European Space Agency (ESA) has shown the device to be of major interest in the areas of image processing and fault tolerance. An SEU and total dose evaluation program has been carried out using Californium-252, a Tandem Accelerator, Cobalt-60 and 150 keV X-rays. The SEU Threshold was found to be about 3 (MeV.cm2/mg) and the limiting Cross-Section 2x10-6 cm2 per bit at an LET of 43 (MeV.cm2/mg). The total dose hardness was found to be in the range of 35-50 Krads and to be dose-rate sensitive.
Keywords :
Extraterrestrial measurements; Fault tolerance; Manufacturing; Microprocessors; Performance evaluation; Random access memory; Read-write memory; Single event upset; Software testing; System testing;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.1987.4337559
Filename :
4337559
Link To Document :