• DocumentCode
    914605
  • Title

    Calculation of forces on the stator end windings of turbogenerator by the transient quasi-3D method

  • Author

    Wen, Xuhui ; Yao, Ruoping ; Tegopoulos, J.A.

  • Author_Institution
    Inst. of Electr. Eng., Acad. Sinica, Beijing, China
  • Volume
    32
  • Issue
    3
  • fYear
    1996
  • fDate
    5/1/1996 12:00:00 AM
  • Firstpage
    1669
  • Lastpage
    1672
  • Abstract
    The Lorentz formula is applied to the calculation of the electromagnetic forces acting on the stator end windings of a turbogenerator within the first several periods after it is suddenly short-circuited, based on the magnetic field computed by the transient quasi-3D method (TQM). The principle of TQM and its essence-processing of winding currents-have been discussed. In the example, the forces acting on the stator end windings of a 35 MW turbogenerator have been computed, when it is under no-load three-phase, no-load line-to-line and no-load line-to-neutral sudden short circuit conditions. Some useful results are obtained
  • Keywords
    electromagnetic fields; electromagnetic forces; machine theory; stators; transient analysis; turbogenerators; 35 MW; Lorentz formula; electromagnetic forces; magnetic field; short circuit conditions; stator end windings; transient quasi-3D method; turbogenerator; winding currents; Circuits; Coils; Electromagnetic forces; Electromagnetic transients; Force measurement; Magnetic circuits; Magnetic fields; Partial response channels; Stator windings; Total quality management; Turbogenerators;
  • fLanguage
    English
  • Journal_Title
    Magnetics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9464
  • Type

    jour

  • DOI
    10.1109/20.497576
  • Filename
    497576