DocumentCode :
914605
Title :
Calculation of forces on the stator end windings of turbogenerator by the transient quasi-3D method
Author :
Wen, Xuhui ; Yao, Ruoping ; Tegopoulos, J.A.
Author_Institution :
Inst. of Electr. Eng., Acad. Sinica, Beijing, China
Volume :
32
Issue :
3
fYear :
1996
fDate :
5/1/1996 12:00:00 AM
Firstpage :
1669
Lastpage :
1672
Abstract :
The Lorentz formula is applied to the calculation of the electromagnetic forces acting on the stator end windings of a turbogenerator within the first several periods after it is suddenly short-circuited, based on the magnetic field computed by the transient quasi-3D method (TQM). The principle of TQM and its essence-processing of winding currents-have been discussed. In the example, the forces acting on the stator end windings of a 35 MW turbogenerator have been computed, when it is under no-load three-phase, no-load line-to-line and no-load line-to-neutral sudden short circuit conditions. Some useful results are obtained
Keywords :
electromagnetic fields; electromagnetic forces; machine theory; stators; transient analysis; turbogenerators; 35 MW; Lorentz formula; electromagnetic forces; magnetic field; short circuit conditions; stator end windings; transient quasi-3D method; turbogenerator; winding currents; Circuits; Coils; Electromagnetic forces; Electromagnetic transients; Force measurement; Magnetic circuits; Magnetic fields; Partial response channels; Stator windings; Total quality management; Turbogenerators;
fLanguage :
English
Journal_Title :
Magnetics, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9464
Type :
jour
DOI :
10.1109/20.497576
Filename :
497576
Link To Document :
بازگشت