DocumentCode
914605
Title
Calculation of forces on the stator end windings of turbogenerator by the transient quasi-3D method
Author
Wen, Xuhui ; Yao, Ruoping ; Tegopoulos, J.A.
Author_Institution
Inst. of Electr. Eng., Acad. Sinica, Beijing, China
Volume
32
Issue
3
fYear
1996
fDate
5/1/1996 12:00:00 AM
Firstpage
1669
Lastpage
1672
Abstract
The Lorentz formula is applied to the calculation of the electromagnetic forces acting on the stator end windings of a turbogenerator within the first several periods after it is suddenly short-circuited, based on the magnetic field computed by the transient quasi-3D method (TQM). The principle of TQM and its essence-processing of winding currents-have been discussed. In the example, the forces acting on the stator end windings of a 35 MW turbogenerator have been computed, when it is under no-load three-phase, no-load line-to-line and no-load line-to-neutral sudden short circuit conditions. Some useful results are obtained
Keywords
electromagnetic fields; electromagnetic forces; machine theory; stators; transient analysis; turbogenerators; 35 MW; Lorentz formula; electromagnetic forces; magnetic field; short circuit conditions; stator end windings; transient quasi-3D method; turbogenerator; winding currents; Circuits; Coils; Electromagnetic forces; Electromagnetic transients; Force measurement; Magnetic circuits; Magnetic fields; Partial response channels; Stator windings; Total quality management; Turbogenerators;
fLanguage
English
Journal_Title
Magnetics, IEEE Transactions on
Publisher
ieee
ISSN
0018-9464
Type
jour
DOI
10.1109/20.497576
Filename
497576
Link To Document