DocumentCode :
914928
Title :
Effect of mechanical vibration on the behavior of partial discharges in generator windings
Author :
Wu, Kai ; Kanegami, Masaki ; Takahashi, Toshihiro ; Suzuki, Hiroshi ; Ito, Tetsuo ; Okamoto, Tatsuki ; Yano, Hiroshi
Author_Institution :
State Key Lab. of Electr. Insulation & Power Equip., Xi´´an Jiaotong Univ., China
Volume :
13
Issue :
2
fYear :
2006
fDate :
4/1/2006 12:00:00 AM
Firstpage :
345
Lastpage :
352
Abstract :
As mechanical vibration usually exists in HV motors and generators, its influence on the partial discharge (PD) needs to be studied so as to improve the reliability of on-line PD monitoring method. In this report, the mechanical vibration frequency was synchronized to the power frequency and the effects of vibration phase and frequency were investigated. Because the length of the discharge gap changed with the vibration, obvious variation in the slot-PD patterns was observed at different vibration lead phase and frequency. Moreover, when the vibration amplitude was large, it was also found that the PD behavior at low voltage just above the PD inception voltage was different from that at higher voltage. This was explained in terms of the effects of the field variation in the gap due to the vibration and the charges left on the insulating surface due to PD.
Keywords :
coils; electric generators; machine insulation; machine windings; monitoring; partial discharge measurement; synchronisation; vibrations; HV motor; discharge gap; generator winding; insulation surface; mechanical vibration; on-line PD monitoring method; partial discharge; power frequency; slot-PD pattern; synchronisation;
fLanguage :
English
Journal_Title :
Dielectrics and Electrical Insulation, IEEE Transactions on
Publisher :
ieee
ISSN :
1070-9878
Type :
jour
DOI :
10.1109/TDEI.2006.1624279
Filename :
1624279
Link To Document :
بازگشت