• DocumentCode
    915049
  • Title

    Intrinsic Average Power Limitation of Coaxial Transmission Line for UHF-TV Five Megawatt Operation

  • Author

    Greenway, Thomas H.

  • Author_Institution
    Greenway Associates
  • Issue
    3
  • fYear
    1984
  • Firstpage
    82
  • Lastpage
    85
  • Abstract
    The power handling capability of coaxial transmission line is intrinsically limited by the onset of the TE 1,1 waveguide mode. An expression is developed for this limitation as a function of operating frequency, and ramifications are examined for UHF-TV operation at the maximum licensure E R P of 5 Megawatts.
  • Keywords
    Coaxial components; Conducting materials; Conductors; Cutoff frequency; Enterprise resource planning; Equations; Power transmission lines; Tellurium; Temperature; Transmission line antennas;
  • fLanguage
    English
  • Journal_Title
    Broadcasting, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9316
  • Type

    jour

  • DOI
    10.1109/TBC.1984.266521
  • Filename