Abstract :
As the silicon technology approaches to its physical limit, the future electronic devices will depend on behaviors of a few electrons. This study is to explore the possibility of detecting a single electron spin transition by using nondestructive evanescent microwave microscopy (EMM) techniques. To enhance the RF magnetic field and minimize the dielectric losses, the sample is placed at the center of the conventional electron spin resonance (ESR) microwave cavity that does not have scanning image capabilities. In this paper, a magnetic dipole probe (MDP) is presented that not only has the advantages of the microwave cavity, but is also capable of surface scanning at high speeds. At present, the minimum detectable electron spin transitions are 20 000 on the ruby crystal (Cr3+ doped in Al2O3) surface, whereas the commercially available ESR microwave cavity has a resolution of 106 minimum detectable spins limit. Three ESR energy absorption spikes were detected at 3.77 and 3.73 GHz with the ruby crystal placed inside and outside of the MDP conductor loop, respectively. The measured ESR energy absorption spectra are consistent with theoretical analysis and the conventional ESR experimental results. The current MDP sensor has a 500-mum spatial resolution with a 1-mm radius conductor loop made by 150-mum copper wires. The nondestructive and noninvasive natures of the EMM microscopy are suitable for many biomedical applications, such as DNA sequencing, Alzheimer, and other biological tissue studies. Future efforts will be focused on integration of the MDP on the atomic force microscopy with carbon-nanotube bridges
Keywords :
chromium; magnetic sensors; paramagnetic resonance; ruby; 1 mm; 150 micron; 3.73 GHz; 3.77 GHz; 500 micron; Al2O3:Cr3+; ESR energy absorption spectra; ESR energy absorption spikes; ESR microwave cavity; MDP conductor loop; MDP sensor; RF magnetic field; copper wires; dielectric losses; electron spin resonanc microwave cavity; electron spin transitions; magnetic dipole probe; nondestructive evanescent microwave microscopy techniques; ruby crystal; single electron spin transition; surface electron spin resonance; surface scanning; Atomic force microscopy; Conductors; Dielectric losses; Electromagnetic wave absorption; Electron microscopy; Microwave devices; Microwave theory and techniques; Paramagnetic resonance; Radio frequency; Silicon; Atomic force microscopy (AFM); biomedical magnetic resonance imaging; electron spin resonance (ESR); microwave spectroscopy; paramagnetic resonance;
fLanguage :
English
Journal_Title :
Sensors Journal, IEEE
Publisher :
ieee
ISSN :
1530-437X
Type :
jour
DOI :
10.1109/JSEN.2006.886887
Filename :
4049786
Link To Document :
بازگشت