Title :
Form factor method yields thermal conductivity and radiated power of nitrogen arc
Author :
Pflanz, Herbert M. ; Horst, Diederik Th J Ter
Author_Institution :
Power Breaker Division, Allis-Chalmers, Boston, Mass.
Volume :
59
Issue :
4
fYear :
1971
fDate :
4/1/1971 12:00:00 AM
Firstpage :
601
Lastpage :
604
Abstract :
The form factor method for the determination of thermal conductivity is applied to experimental results obtained with a cascade arc in nitrogen. Experimental and theoretical thermal conductivities agree, even at temperatures above 10000°K if rather high radiation losses are taken into account. This result does not change significantly when reabsorption is considered by means of an absorption form factor and the total absorbed power.
Keywords :
Conductivity measurement; Current density; Electric variables measurement; Equations; Nitrogen; Shape measurement; Temperature measurement; Thermal conductivity; Thermal factors; Voltage;