DocumentCode :
917808
Title :
Prebreakdown current and charge flow in long positive point-plane gaps with impulse-voltage waves having times to crest in the range 15--1200 μs
Author :
Jones, B. ; Whittington, H.W.
Author_Institution :
Central Electricity Research Laboratories, Electrical Engineering Division, Leatherhead, UK
Volume :
8
Issue :
10
fYear :
1972
Firstpage :
264
Lastpage :
265
Abstract :
Measurements of prebreakdown current and charge flow in long positive point-plane gaps have shown a critical charge injection which is a function of time to peak of the voltage wave. With increasing time to peak, the pattern of current flow changes from a single large-amplitude pulse to a series of discrete pulses of lower amplitude but of similar duration.
Keywords :
discharges (electric); electric breakdown; electric breakdown of gases; spark gaps; sparks; charge flow; charge injection; gaps with impulse voltage waves; point plane gaps; prebreakdown current;
fLanguage :
English
Journal_Title :
Electronics Letters
Publisher :
iet
ISSN :
0013-5194
Type :
jour
DOI :
10.1049/el:19720195
Filename :
4235647
Link To Document :