• DocumentCode
    9181
  • Title

    Calibration of Electromagnetic Dot Sensor—Part 2: D-Dot Mode

  • Author

    Al Agry, Ahmad ; Schill, Robert A.

  • Author_Institution
    Dept. of Electr. & Comput. Eng., Univ. of Nevada at Las Vegas, Las Vegas, NV, USA
  • Volume
    14
  • Issue
    9
  • fYear
    2014
  • fDate
    Sept. 2014
  • Firstpage
    3111
  • Lastpage
    3118
  • Abstract
    Theoretical and experimental calibration studies are presented in this paper pertaining to the EM-dot in D-dot mode. Calibration theories are verified with experimental calibration studies. Absolute measurements are accurate to within a 1.3% in D-dot mode based on the entire history of the calibration signal originating and terminating in noise. More significantly, within a 95% noise confidence interval, the EM-dot tracks the reference test stand signal over 78.2% of the entire history of the calibration pulse stimulus.
  • Keywords
    calibration; electric field measurement; electric sensing devices; electromagnetic devices; magnetic field measurement; magnetic sensors; D-dot mode; EM-dot mode; calibration pulse stimulus; electromagnetic dot sensor; noise confidence interval; Calibration; Capacitance; Couplings; Loading; Oscilloscopes; Sensors; Wires; D-dot; electromagnetic sensor; pulsed power;
  • fLanguage
    English
  • Journal_Title
    Sensors Journal, IEEE
  • Publisher
    ieee
  • ISSN
    1530-437X
  • Type

    jour

  • DOI
    10.1109/JSEN.2014.2324596
  • Filename
    6817515