• DocumentCode
    918204
  • Title

    Influence of Sampling Period on a Class of Optimal Fault-Detection Performance

  • Author

    Zhang, Ping ; Ding, Steven X.

  • Author_Institution
    Inst. for Autom. Control & Complex Syst., Univ. of Duisburg-Essen, Duisburg
  • Volume
    54
  • Issue
    6
  • fYear
    2009
  • fDate
    6/1/2009 12:00:00 AM
  • Firstpage
    1396
  • Lastpage
    1402
  • Abstract
    In this note, the influence of sampling period on a widely accepted class of optimal fault-detection performance is studied. The background of this study is the important role played by the sampling period in embedded networked control systems. It is shown that the optimal H infin/H infin fault-detection performance index will become worse, if the sampling period is increased by an integer multiple. The main tool used for the analysis is the lifting technique, which bridges systems with different sampling periods.
  • Keywords
    Hinfin control; control engineering computing; optimal control; performance index; bridge system; embedded networked control system; optimal Hinfin/Hinfin fault-detection; sampling period; Automatic control; Bridges; Communication system control; Control systems; Fault detection; Fault diagnosis; Networked control systems; Performance analysis; Performance gain; Sampling methods; Embedded networked control systems; fault detection; lifting; optimal design; sampling period;
  • fLanguage
    English
  • Journal_Title
    Automatic Control, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9286
  • Type

    jour

  • DOI
    10.1109/TAC.2009.2015563
  • Filename
    4982653