DocumentCode
918612
Title
Harmonic Analysis of SAW Transducers
Author
Panasik, Carl M. ; Hunsinger, Bill J.
Volume
26
Issue
6
fYear
1978
fDate
6/1/1978 12:00:00 AM
Firstpage
447
Lastpage
450
Abstract
The excitation function of an interdigital transducer (IDT) is determined by measuring the discrete impulse response, taking into account the first seven harmonics of the frequency domain. Using a time segregation method, all non-SAW time-domain components are suppressed. A single transducer is isolated by a method of autodeconvolution that utilizes a theoreticalIy derived phase function. The resulting excitation function provides experimental insight into the operation of IDT electrodes and compares well with the theoretical response of Smith and Pedler. The basic analysis technique can be used for other configurations, once the frequency-domain phase response of one transducer is known.
Keywords
Acoustic transducers; Delay effects; Frequency measurement; Harmonic analysis; Sampling methods; Surface acoustic waves; Time domain analysis; Time measurement; Transfer functions; Voltage;
fLanguage
English
Journal_Title
Microwave Theory and Techniques, IEEE Transactions on
Publisher
ieee
ISSN
0018-9480
Type
jour
DOI
10.1109/TMTT.1978.1129411
Filename
1129411
Link To Document