• DocumentCode
    920971
  • Title

    Data acquisition for the HILI detector

  • Author

    Teh, K.M. ; Shapira, D. ; McConnell, J.W. ; Kim, H. ; Novotny, R.

  • Author_Institution
    Oak Ridge Nat. Lab., TN, USA
  • Volume
    35
  • Issue
    1
  • fYear
    1988
  • Firstpage
    272
  • Lastpage
    276
  • Abstract
    A large acceptance, multisegmented detector system capable of the simultaneous detection of heavy ions and light ions (HILI) has been constructed. The heavy ions are detected with a segmented gas-ionization chamber and a multiwire proportional counter, while the light ions are detected with a 192-element plastic ´phoswich´ hodoscope. Processing the large number of signals is accomplished through a combination of CAMAC and FASTBUS modules and preprocessors and a host minicomputer. Details of the data acquisition system and the reasons for adopting a dual-standard system are discussed. A technique for processing signals from an individual hodoscope detector is presented.<>
  • Keywords
    CAMAC; computer interfaces; computerised signal processing; ionisation chambers; physics computing; position sensitive particle detectors; proportional counters; CAMAC; FASTBUS; HILI detector; data acquisition; dual-standard system; multisegmented detector system; multiwire proportional counter; preprocessors; segmented gas-ionization chamber; signal processing; CAMAC; Data acquisition; Event detection; Fastbus; Ionization chambers; Physics; Plastics; Radiation detectors; Signal processing; Solid scintillation detectors;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/23.12722
  • Filename
    12722