    Stall protection of large induction motors

  • Author

    DeCastro, Jose E. ; Beck, Roy T. ; Cai, Charles ; Yu, Luke

  • Author_Institution
    Ralph M. Parsons Co., Pasadena, CA, USA
  • Volume
    31
  • Issue
    5
  • fYear
    1995
  • Firstpage
    1159
  • Lastpage
    1166
  • Abstract
    Large induction motors driving high inertia loads, such as fans, blowers, and reciprocating compressors, may take a longer time to accelerate to full speed than their allowable (safe) stall time. This paper discusses the available types of stall protection for motors whose starting time exceeds their allowable stall time
  • Keywords
    compressors; induction motor protection; load (electric); relay protection; starting; blowers; fans; high inertia loads; induction motors; reciprocating compressors; stall protection; stall time; starting time; Acceleration; Chemical industry; Induction motors; Insulation; Petroleum; Protection; Rotors; Stator windings; Temperature; Voltage;