DocumentCode :
923158
Title :
Measurement of scattering parameters at 35 GHz using amplitude-modulated homodyne detection
Author :
Wood, M.A.
Author_Institution :
Royal Signals and Radar Establishment, Malvern, UK
Volume :
129
Issue :
6
fYear :
1982
fDate :
12/1/1982 12:00:00 AM
Firstpage :
363
Lastpage :
366
Abstract :
An improved calibration scheme for a homodyne network analyser is described. The effects of residual phase modulation in the test channel are discussed and are shown to be eliminated by the calibration scheme. Results are presented for measurements performed at 35 GHz, and measurements of |S11| are in agreement with a precision tuned reflectometer to better than ¿¿ 0.002.
Keywords :
S-parameters; amplitude modulation; calibration; microwave measurement; network analysers; 35 GHz; amplitude-modulated homodyne detection; calibration; homodyne network analyser; homodyne reflectometer; measurements; phase modulation; precision tuned reflectometer; scattering parameters; test channel;
fLanguage :
English
Journal_Title :
Microwaves, Optics and Antennas, IEE Proceedings H
Publisher :
iet
ISSN :
0143-7097
Type :
jour
DOI :
10.1049/ip-h-1.1982.0073
Filename :
4645521
Link To Document :
بازگشت