DocumentCode
923920
Title
Transient Response of a Narrow-Band Automatic Frequency-Control System
Author
Miller, Theodore
Author_Institution
Westinghouse Research Laboratories, Westinghouse Electric Corp., East Pittsburgh, Pa.
Volume
39
Issue
11
fYear
1951
Firstpage
1433
Lastpage
1436
Abstract
A method of analyzing the response of automatic frequency-control systems, operating in conjunction with a narrow band-pass filter, is presented in this paper. A time-lag, equivalent to the reciprocal of the bandwidth, is assigned to the filter. Circuit parameters are established for operation near the critically damped response condition. The equations of the system are derived with the aid of the Laplace transform. The method of residues is used to evaluate the transient response to a step-input frequency disturbance.
Keywords
Automatic frequency control; Band pass filters; Circuits; Delay; Laplace equations; Local oscillators; Narrowband; Proportional control; Transient response; Voltage;
fLanguage
English
Journal_Title
Proceedings of the IRE
Publisher
ieee
ISSN
0096-8390
Type
jour
DOI
10.1109/JRPROC.1951.273608
Filename
4050566
Link To Document