DocumentCode
925501
Title
Sensitivity of the Total Power Radiometer with Periodic Absolute Calibration
Author
Hersman, Michael S. ; Poe, Gene A.
Volume
29
Issue
1
fYear
1981
fDate
1/1/1981 12:00:00 AM
Firstpage
32
Lastpage
40
Abstract
The total power radiometer is an attractive choice for imaging applications due to its high sensitivity and simple configuration. However, available theoretical results are inadequate to allow an accurate radiometer performance prediction in the presence of receiver gain fluctuations and other receiver characteristics with nonuniform fluctuation power spectra. An improved analysis of the total power radiometer Delta T is presented in terms of the receiver output fluctuation power spectral density and a transfer function due to postdetection filtering and periodic calibration. Verification of this analysis is obtained by measuring the fluctuation power spectrum of a 94-GHz receiver and comparing the predicted Delta T with a direct measurement. Numerical results including application to an example radiometer system are presented. These results indicate that the total power radiometer should function well in short integration time, periodically calibrated radiometer systems.
Keywords
Calibration; Circuit noise; Diodes; Electron devices; Fluctuations; Microwave radiometry; Oscillators; Performance gain; Power harmonic filters; Power measurement;
fLanguage
English
Journal_Title
Microwave Theory and Techniques, IEEE Transactions on
Publisher
ieee
ISSN
0018-9480
Type
jour
DOI
10.1109/TMTT.1981.1130283
Filename
1130283
Link To Document