DocumentCode :
927814
Title :
A Scanner for Rapid Measurement of Envelope Delay Distortion
Author :
Hunt, Loyd E. ; Albersheim, W.J.
Author_Institution :
Bell Telephone Laboratories, Deal, N.J.
Volume :
40
Issue :
4
fYear :
1952
fDate :
4/1/1952 12:00:00 AM
Firstpage :
454
Lastpage :
459
Abstract :
A measuring device is described which instantaneously displays the envelope delay-frequency characteristic on a cathode-ray screen. Loop and one-way measurements of long-distance radio networks can be carried out. The frequency range extends from 60 to 80 megacycles; the limits of accuracy are 1 millimicrosecond or 2 per cent of the measured delay range. Comparison of two characteristics can be carried out by superposition of alternate scanning traces. The device has been found useful in measuring the delay distortion of the TD-2 radio-relay system and in designing and adjusting the delay equalizers needed to correct it.
Keywords :
Area measurement; Circuits; Current measurement; Delay; Distortion measurement; Equalizers; Frequency measurement; Phase measurement; Relays; Senior members;
fLanguage :
English
Journal_Title :
Proceedings of the IRE
Publisher :
ieee
ISSN :
0096-8390
Type :
jour
DOI :
10.1109/JRPROC.1952.274040
Filename :
4050970
Link To Document :
بازگشت