• DocumentCode
    930723
  • Title

    High-resolution measurement of polarization dependent loss

  • Author

    Nyman, Bruce M. ; Wolter, Gregory

  • Author_Institution
    AT&T Bell Lab., Holmdel, NJ, USA
  • Volume
    5
  • Issue
    7
  • fYear
    1993
  • fDate
    7/1/1993 12:00:00 AM
  • Firstpage
    817
  • Lastpage
    818
  • Abstract
    Polarization-dependent loss (PDL) is the dependence of insertion loss on the state of polarization (SOP) of the input light. Previous efforts to measure PDL of components had an uncertainty of more than 0.01 dB, primarily due to the PDL of the measurement equipment itself. A method that uses an erbium-doped-fiber depolarizer, resulting in a test set with an uncertainty of+or-0.001 dB, is presented.<>
  • Keywords
    measurement errors; optical losses; optical polarisers; optical resolving power; Er-doped fibre depolariser; erbium-doped-fiber depolarizer; high resolution measurement; input light; insertion loss; measurement equipment; measurement uncertainty; polarization dependent loss; state of polarization; Detectors; Erbium; Loss measurement; Optical fiber devices; Optical fiber polarization; Optical polarization; Optimized production technology; Page description languages; Polarization mode dispersion; Testing;
  • fLanguage
    English
  • Journal_Title
    Photonics Technology Letters, IEEE
  • Publisher
    ieee
  • ISSN
    1041-1135
  • Type

    jour

  • DOI
    10.1109/68.229817
  • Filename
    229817