Abstract
The delay time of voltage breakdown has been analyzed as a function of the time interval to preceding interruption of high currents. With intervals >1 ms the behavior of the gap corresponded to cold electrodes. For this case, in a separate experiment, the dependence of the delay time on various parameters has been studied. At constant voltage a steep increased with the gap distance was found. This leads to the conclusion that field emission rather than a clump process is responsible for late breakdowns
Keywords
circuit breakers; electric breakdown; electron field emission; vacuum insulation; cold electrodes; constant voltage; field emission; gap distance; microsecond delay time; voltage breakdown; Delay effects; Dielectric breakdown; Electric breakdown; Electrodes; Electron emission; Interrupters; Physics; Plasma transport processes; Vacuum breakdown; Voltage;