• DocumentCode
    932555
  • Title

    Breakdown characteristics of He gas at cryogenic temperature and low pressure

  • Author

    Irmisch, M. ; Ulbricht, A. ; Zwecker, V. ; Badent, R. ; Hinderer, A. ; Olbrisch, J. ; Jaarah, M.

  • Author_Institution
    Kernforschungszentrum Karlsruhe, Inst. fuer Tech. Phys., Germany
  • Volume
    28
  • Issue
    4
  • fYear
    1993
  • fDate
    8/1/1993 12:00:00 AM
  • Firstpage
    507
  • Lastpage
    511
  • Abstract
    The breakdown of He between plane electrodes was investigated under conditions similar to those of the operation of superconducting magnets at room temperature and 4 K. It was found that the breakdown voltage in the Paschen minimum was higher than expected at room temperature, which was explained by the presence of impurity. An additional effect observed, especially at low pressures, is that the measured pressure in the vacuum vessel does not seem to agree with the pressure of the electrode gap. Furthermore a helium leak of 1 Pa 1/s was introduced between the electrodes. No measurable influence of this leak was found within the measuring accuracy at low temperatures
  • Keywords
    electric breakdown of gases; helium; He; Paschen minimum; breakdown voltage; cryogenic temperature; electrode gap; impurity; leak; measuring accuracy; plane electrodes; Coils; Cryogenics; Electric breakdown; Electrodes; Helium; Insulation; Magnetic field measurement; Pollution measurement; Superconducting magnets; Temperature;
  • fLanguage
    English
  • Journal_Title
    Electrical Insulation, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9367
  • Type

    jour

  • DOI
    10.1109/14.231533
  • Filename