• DocumentCode
    934427
  • Title

    Simulation Study of the Role Played by Intensifying or Support Layers in Scintillation Screens

  • Author

    Pistrui-Maximean, S.A. ; Freud, N. ; Létang, J.M. ; Walenta, A.H. ; Koch, A. ; Montarou, G. ; Babot, D.

  • Author_Institution
    INSA-Lyon, Lyon
  • Volume
    54
  • Issue
    3
  • fYear
    2007
  • fDate
    6/1/2007 12:00:00 AM
  • Firstpage
    699
  • Lastpage
    705
  • Abstract
    The advantage of using reinforcing substrate layers with phosphor screens is that they increase the phosphor sensitivity and filter the scattered radiation, while providing a mechanical support for the phosphor layer. A simulation model based on the Monte Carlo code Geant4 was developed to study the influence of the substrate properties (material, thickness) on the phosphor screen spatial response. The optimal substrate/phosphor combinations have been determined at given sensitivity of the screen. Of all studied cases at medium energy (300 keV), a configuration with slight improvement in the screen spatial response has been found. Moreover, the results show that, without degrading the performances of the screen, the phosphor thickness may be significantly reduced (by 35% in the case of a 0.05 mm Pb substrate). Besides, PolyEthylene Terephthalate (PET) makes a good mechanical support (of up to minimum 4 mm in thickness) for the phosphor layer. The simulation methodology permitted to study the role played by the X-ray and electron processes inside the substrate layer.
  • Keywords
    Monte Carlo methods; X-ray absorption; X-ray imaging; optical filters; phosphors; scintillation; shielding; solid scintillation detectors; Monte Carlo code Geant4; X-ray processes; electron processes; electron volt energy 300 keV; phosphor screens; phosphor thickness; polyethylene terephthalate; reinforcing substrate layers; scattered radiation filter; scintillation screens; Degradation; Detectors; Electrons; Image edge detection; Laboratories; Optical imaging; Phosphors; Portals; X-ray detection; X-ray imaging; Geant4; Monte Carlo simulation; X-ray imaging; modulation transfer function; phosphor screen; reinforcing screen;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.2007.895046
  • Filename
    4237422