Title :
Assessment of left ventricular ejection fraction from technetium-99m-methoxy isobutyl isonitrile multiple-gated radionuclide angiocardiography
Author :
Davis, Malcolm H. ; Rezaie, Bahman ; Weiland, Frederick L.
Author_Institution :
Dept. of Electr. Eng., St. Mary´´s Univ., San Antonio, TX, USA
fDate :
6/1/1993 12:00:00 AM
Abstract :
Abnormal left ventricular function is a diagnostic indication of cardiac disease. Left ventricular function is commonly quantified by ejection fraction measurements. A novel approach for the determination of left ventricular ejection fraction from technetium-99m-methoxy isobutyl isonitrile multiple-gated radionuclide angiocardiography is presented. Data from 23 patients, symptomatic of cardiac disease, indicate that ejection fractions determined using the radionuclide technique correlate well with contrast X-ray single-plane cineangiography (r=0.83, p<10-6). Data from 14 of the patients indicate favorable correlation with technetium-99m-pertechnetate gated blood pool radionuclide angiocardiography (r=0.87, p<10-4)
Keywords :
cardiology; radioisotope scanning and imaging; 99mTc-methoxy isobutyl isonitrile; cardiac disease; contrast X-ray single-plane cineangiography; diagnostic indication; left ventricular ejection fraction; medical diagnostic imaging; multiple-gated radionuclide angiocardiography; nuclear medicine; Angiocardiography; Blood; Cardiac disease; Heart; Image processing; Image sampling; Myocardium; Performance evaluation; Pixel; RNA;
Journal_Title :
Medical Imaging, IEEE Transactions on