• DocumentCode
    937094
  • Title

    Vector-velocity estimation in swept-scan using a K-space approach

  • Author

    Jeng, Geng-Shi ; Li, Pai-Chi

  • Author_Institution
    Dept. of Electr. Eng., Nat. Taiwan Univ., Taipei
  • Volume
    53
  • Issue
    5
  • fYear
    2006
  • fDate
    5/1/2006 12:00:00 AM
  • Firstpage
    947
  • Lastpage
    958
  • Abstract
    The swept-scan technique (i.e., continuously moving a single-crystal transducer during pulse-echo data acquisition) is used in high-frequency, ultrasonic flow imaging. Relative to the conventional step-scan technique, swept scanning improves the rate of data acquisition and enables near-real-time, high-frequency color flow mapping. However, the continuous transducer movement may have nonnegligible effects on accuracy of velocity estimation. This paper introduces a spatial frequency domain (i.e., k-space) approach that quantifies the effects of both lateral and axial motions in a swept scan. It is shown that the k-space representation is equivalent to a Doppler-radio frequency (RF) frequency domain representation, and that transducer movement in the swept-scan technique results in a change in Doppler bandwidth. In addition, a vector velocity estimator is developed based on the proposed k-space approach. Both simulations and flow-phantom experiments were performed to evaluate the performance of the proposed vector velocity estimator. A 45-MHz transducer was scanned at 20 mm/s. The Doppler angle ranged from 29deg to 90deg, and the flow velocities ranged from 15 to 30 mm/s. The results show that the proposed k-space vector velocity estimator exhibited a mean error of 2.6deg for flow-direction estimation, with the standard deviation ranging from 2.2deg to 8.2deg. In comparison, for the conventional spectral-broadening-based vector velocity estimator ignoring the swept-scan effect, the mean error became 15deg and the standard deviations were from 2.7deg to 6.6deg
  • Keywords
    Doppler measurement; biomedical transducers; biomedical ultrasonics; estimation theory; frequency-domain analysis; phantoms; ultrasonic transducers; Doppler-radio frequency frequency domain representation; flow phantom; high-frequency ultrasonic flow imaging; k-space representation; near-real-time high-frequency color flow mapping; pulse-echo data acquisition; single-crystal transducer; step-scan technique; swept-scan technique; transducer movement; vector velocity estimator; vector-velocity estimation; Bandwidth; Data acquisition; Frequency domain analysis; Performance evaluation; Radio frequency; Speckle; Ultrasonic imaging; Ultrasonic transducers; Ultrasonic variables measurement; Velocity measurement;
  • fLanguage
    English
  • Journal_Title
    Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-3010
  • Type

    jour

  • DOI
    10.1109/TUFFC.2006.1632685
  • Filename