Title :
An iterative synthetic aperture imaging algorithm with correction of diffraction effects
Author :
Wennerström, Erik ; Stepinski, Tadeusz ; Olofsson, Tomas
Author_Institution :
Signals & Syst. Group, Uppsala Univ.
fDate :
5/1/2006 12:00:00 AM
Abstract :
In this paper we present an iterative version of the synthetic aperture imaging algorithm extended synthetic aperture technique (ESAFT) proposed recently. The algorithm is based on a linear model that accounts for the distortions effects of an imaging system used for acquisition of ultrasonic data. Improved resolution (both lateral and temporal) in the reconstructed image is obtained as a result of minimizing the reconstruction mean square error. In this work, the minimization is extended to parameters that characterize expected amplitudes of each image element in the area of interest. An iterative optimization scheme is proposed, which in each step performs minimization of the reconstruction error based on the parameter matrix found in the previous step. Comparing to ESAFT, the proposed approach yields a significant improvement in resolution and a high degree of robustness with regard to initial choice of the parameter matrix. Performance of the proposed algorithm is evaluated using both real and simulated ultrasonic data
Keywords :
image reconstruction; image resolution; iterative methods; mean square error methods; optimisation; ultrasonic diffraction; ultrasonic imaging; correction effects; diffraction effects; image reconstruction; iterative optimization scheme; iterative synthetic aperture imaging algorithm; lateral resolution; mean square error method; temporal resolution; Acoustic transducers; Covariance matrix; Diffraction; Focusing; Image reconstruction; Image resolution; Iterative algorithms; Synthetic aperture sonar; Ultrasonic imaging; Ultrasonic transducers;
Journal_Title :
Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
DOI :
10.1109/TUFFC.2006.1632690