DocumentCode
938127
Title
A Phase Measuring System for Short RF Pulses
Author
Sparks, Richard A.
Author_Institution
Emerton, Inc., Silver Spring, Md.
Issue
3
fYear
1962
Firstpage
298
Lastpage
302
Abstract
The phase measuring system described in this paper was developed primarily for the purpose of determining the phase variation along a narrow RF pulse generated by a high-power traveling-wave tube. This techniques is also suitable for the precision measurement of relative phase shifts that arise when the tube parameters are varied over their operating range. It is a two-channel system that employs a balanced modulator to derive an offset signal and utilizes a homodyne detector to translate the phase information to a high intermediate frequency. This particular null technique ensures high accuracy even when a comparison is to be made over a wide range of signal amplitudes.
Keywords
Acoustic pulses; Acoustic sensors; Attenuation measurement; Jacobian matrices; Microwave measurements; Phase measurement; Power measurement; Pulse measurements; Radio frequency; Solids;
fLanguage
English
Journal_Title
Instrumentation, IRE Transactions on
Publisher
ieee
ISSN
0096-2260
Type
jour
DOI
10.1109/IRE-I.1962.5006649
Filename
5006649
Link To Document