DocumentCode :
938241
Title :
Impedance Measurement in Frequency-Halving Networks Using a Two-Frequency Synthetic Loading Technique
Author :
Harrison, Robert G. ; Kalivas, Grigorios A.
Volume :
32
Issue :
12
fYear :
1984
fDate :
12/1/1984 12:00:00 AM
Firstpage :
1591
Lastpage :
1597
Abstract :
A technique is described which removes a major difficulty in the design of wide-band frequency-halving networks: the accurate characterization of the "pumped" input output impedances at the plane of the varactors. The procedure permits the use of realistic input, output power levels with the input at twice the output frequency.
Keywords :
Circuits; Design optimization; Frequency domain analysis; Frequency measurement; Impedance measurement; Narrowband; Position measurement; Power generation; Varactors; Wideband;