DocumentCode :
940278
Title :
Performance Improvement of Shunt Active Power Filter With Dual Parallel Topology
Author :
Asiminoaei, Lucian ; Lascu, Cristian ; Blaabjerg, Frede ; Boldea, Ion
Author_Institution :
Danfoss Drives A/S, Graasten
Volume :
22
Issue :
1
fYear :
2007
Firstpage :
247
Lastpage :
259
Abstract :
This paper describes the control and parallel operation of two active power filters (APFs). Possible parallel operation situations of two APFs are investigated, and then the proposed topology is analyzed. The filters are coupled in a combined topology in which one filter is connected in a feedback loop and the other is in a feedforward loop for harmonic compensation. Thus, both active power filters bring their own characteristic advantages, i.e., the feedback filter improves the steady-state performance of the harmonic mitigation and the feedforward filter improves the dynamic response. Another characteristic of the proposed topology is the possibility of joint operation of both filters either as frequency-sharing or load-sharing, with or without redundancy. The frequency-sharing operation is possible due to the control algorithm, which is based on selective harmonic compensation using equivalent harmonic integrators. Implementation details and a discussion on the efficiency improvement for various switching frequencies are provided. The evaluation of the proposed topology concludes that this approach is very practical for achieving both low and high order harmonic compensation and stable grid operation. This is supported by extensive measurement results on a 15-kVA laboratory setup, indicating a reduction in total harmonic current distortion from the existing 30% to less than 2% for a typical adjustable speed drive application
Keywords :
active filters; harmonic distortion; power harmonic filters; variable speed drives; 15 kVA; adjustable speed drive applications; dual parallel topology; equivalent harmonic integrators; feedback filters; feedback loop; frequency sharing operation; harmonic compensation; harmonic mitigation; high order harmonic compensation; parallel operations; selective harmonic compensation; shunt active power filter; steady-state performance; switching frequency; total harmonic current distortion; Active filters; Current measurement; Distortion measurement; Feedback loop; Power harmonic filters; Power system harmonics; Steady-state; Switching frequency; Topology; Velocity measurement; Active filters; harmonic analysis; interconnected power systems; power system harmonic; pulse width modulated inverters;
fLanguage :
English
Journal_Title :
Power Electronics, IEEE Transactions on
Publisher :
ieee
ISSN :
0885-8993
Type :
jour
DOI :
10.1109/TPEL.2006.888912
Filename :
4052396
Link To Document :
بازگشت