• DocumentCode
    941283
  • Title

    Millimeter-Wave, Shot-Noise Limited, Fixed-Tuned Mixer

  • Author

    Faber, Marek T. ; Archer, John W.

  • Volume
    33
  • Issue
    11
  • fYear
    1985
  • fDate
    11/1/1985 12:00:00 AM
  • Firstpage
    1172
  • Lastpage
    1178
  • Abstract
    In a companion paper, two computer-controlled measurement systems for testing millimeter-wave Schottky-barrier diode mixers between 90 and 350 GHz have been presented. In this paper, a typical application of the measurement system to the testing and evacuation of a practical W-band, cryogenic, fixed-tuned Schottky diode mixer is used to demonstrate the performance of the instruments. The mixer is shown to have a single-sideband noise temperature of less than 140 K between 98 and 118 GHz and, at 110 GHz, achieves shot-noise limited performance, with a SSB noise temperature of only 81 K and corresponding conversion loss of 5.7 dB.
  • Keywords
    Extraterrestrial measurements; Frequency; Impedance; Instruments; Millimeter wave measurements; Mixers; Observatories; Radio astronomy; Schottky diodes; System testing;
  • fLanguage
    English
  • Journal_Title
    Microwave Theory and Techniques, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9480
  • Type

    jour

  • DOI
    10.1109/TMTT.1985.1133190
  • Filename
    1133190