DocumentCode
941283
Title
Millimeter-Wave, Shot-Noise Limited, Fixed-Tuned Mixer
Author
Faber, Marek T. ; Archer, John W.
Volume
33
Issue
11
fYear
1985
fDate
11/1/1985 12:00:00 AM
Firstpage
1172
Lastpage
1178
Abstract
In a companion paper, two computer-controlled measurement systems for testing millimeter-wave Schottky-barrier diode mixers between 90 and 350 GHz have been presented. In this paper, a typical application of the measurement system to the testing and evacuation of a practical W-band, cryogenic, fixed-tuned Schottky diode mixer is used to demonstrate the performance of the instruments. The mixer is shown to have a single-sideband noise temperature of less than 140 K between 98 and 118 GHz and, at 110 GHz, achieves shot-noise limited performance, with a SSB noise temperature of only 81 K and corresponding conversion loss of 5.7 dB.
Keywords
Extraterrestrial measurements; Frequency; Impedance; Instruments; Millimeter wave measurements; Mixers; Observatories; Radio astronomy; Schottky diodes; System testing;
fLanguage
English
Journal_Title
Microwave Theory and Techniques, IEEE Transactions on
Publisher
ieee
ISSN
0018-9480
Type
jour
DOI
10.1109/TMTT.1985.1133190
Filename
1133190
Link To Document