Bias Atlases for Segmentation-Based PET Attenuation Correction Using PET-CT and MR
Author
Jinsong Ouyang ; Se Young Chun ; Petibon, Yoann ; Bonab, Ali A. ; Alpert, Nathaniel ; El Fakhri, Georges
Author_Institution
Center for Adv. Radiol. Sci., Massachusetts Gen. Hosp., Boston, MA, USA
Volume
60
Issue
5
fYear
2013
fDate
Oct. 2013
Firstpage
3373
Lastpage
3382
Abstract
This study was to obtain voxel-wise PET accuracy and precision using tissue-segmentation for attenuation correction. We applied multiple thresholds to the CTs of 23 patients to classify tissues. For six of the 23 patients, MR images were also acquired. The MR fat/in-phase ratio images were used for fat segmentation. Segmented tissue classes were used to create attenuation maps, which were used for attenuation correction in PET reconstruction. PET bias images were then computed using the PET reconstructed with the original CT as the reference. We registered the CTs for all the patients and transformed the corresponding bias images accordingly. We then obtained the mean and standard deviation bias atlas using all the registered bias images. Our CT-based study shows that four-class segmentation (air, lungs, fat, other tissues), which is available on most PET-MR scanners, yields 15.1%, 4.1%, 6.6%, and 12.9% RMSE bias in lungs, fat, non-fat soft-tissues, and bones, respectively. An accurate fat identification is achievable using fat/in-phase MR images. Furthermore, we have found that three-class segmentation (air, lungs, other tissues) yields less than 5% standard deviation of bias within the heart, liver, and kidneys. This implies that three-class segmentation can be sufficient to achieve small variation of bias for imaging these three organs. Finally, we have found that inter- and intra-patient lung density variations contribute almost equally to the overall standard deviation of bias within the lungs.
Keywords
biomedical MRI; bone; fats; image segmentation; lung; medical image processing; positron emission tomography; MR imaging; PET accuracy; PET precision; PET-CT imaging; bias atlases; bones; fat segmentation; four class segmentation; lungs; segmentation based PET attenuation correction; three class segmentation; tissue segmentation; Attenuation; Bones; Computed tomography; Image segmentation; Lungs; Positron emission tomography; Standards; Attenuation correction; PET-MR;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/TNS.2013.2278624
Filename
6600806
Link To Document