    Cryogenic and magnetic tests of the twin aperture prototype dipole in the Saclay test facility

  • Author

    Deregel, J. ; Genevey, P. ; Jacquemin, J.P. ; Kircher, F. ; Le Bars, J. ; Le Coroller, A. ; Henrichsen, K.N. ; Lebrun, P. ; Vlogaert, J.

  • Author_Institution
    CE Saclay, Gif-sur-Yvette, France
  • Volume
    3
  • Issue
    1
  • fYear
    1993
  • fDate
    3/1/1993 12:00:00 AM
  • Firstpage
    777
  • Lastpage
    780
  • Abstract
    The authors describe the test facility and the cryogenic and magnetic measurements performed on the twin aperture prototype (TAP) dipole for the CERN Large Hadron Collider (LHC). The magnet, designed by CERN and built by European industries, was tested in a facility built at CE Saclay. The focus is on the cryogenic system, which enables prototype magnets to be tested in superfluid helium; on the data acquisition systems, including a system for magnetic measurements; and on the results which were obtained during the tests.<>
  • Keywords
    beam handling equipment; cryogenics; data acquisition; proton accelerators; superconducting magnets; synchrotrons; CE Saclay; CERN Large Hadron Collider; European industries; LHC; Saclay test facility; TAP; cryogenic system; data acquisition systems; magnetic measurements; magnetic tests; superfluid He; twin aperture prototype dipole; Apertures; Cryogenics; Data acquisition; Large Hadron Collider; Magnetic variables measurement; Performance evaluation; Prototypes; System testing; Test facilities;
  • fLanguage
    English
  • Journal_Title
    Applied Superconductivity, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    1051-8223
  • Type

    jour

  • DOI
    10.1109/77.233819
  • Filename
    233819