DocumentCode :
944982
Title :
Cryogenic and magnetic tests of the twin aperture prototype dipole in the Saclay test facility
Author :
Deregel, J. ; Genevey, P. ; Jacquemin, J.P. ; Kircher, F. ; Le Bars, J. ; Le Coroller, A. ; Henrichsen, K.N. ; Lebrun, P. ; Vlogaert, J.
Author_Institution :
CE Saclay, Gif-sur-Yvette, France
Volume :
3
Issue :
1
fYear :
1993
fDate :
3/1/1993 12:00:00 AM
Firstpage :
777
Lastpage :
780
Abstract :
The authors describe the test facility and the cryogenic and magnetic measurements performed on the twin aperture prototype (TAP) dipole for the CERN Large Hadron Collider (LHC). The magnet, designed by CERN and built by European industries, was tested in a facility built at CE Saclay. The focus is on the cryogenic system, which enables prototype magnets to be tested in superfluid helium; on the data acquisition systems, including a system for magnetic measurements; and on the results which were obtained during the tests.<>
Keywords :
beam handling equipment; cryogenics; data acquisition; proton accelerators; superconducting magnets; synchrotrons; CE Saclay; CERN Large Hadron Collider; European industries; LHC; Saclay test facility; TAP; cryogenic system; data acquisition systems; magnetic measurements; magnetic tests; superfluid He; twin aperture prototype dipole; Apertures; Cryogenics; Data acquisition; Large Hadron Collider; Magnetic variables measurement; Performance evaluation; Prototypes; System testing; Test facilities;
fLanguage :
English
Journal_Title :
Applied Superconductivity, IEEE Transactions on