DocumentCode
9457
Title
Perturbation On-Time (POT) Technique in Power Factor Correction (PFC) Controller for Low Total Harmonic Distortion and High Power Factor
Author
Tsai, Jen-Chieh ; Chen, Chi-Lin ; Chen, Yi-Ting ; Ni, Chia-Lung ; Chen, Chun-Yen ; Chen, Ke-Horng
Author_Institution
Inst. of Electr. Control Eng., Nat. Chiao Tung Univ., Hsinchu, Taiwan
Volume
28
Issue
1
fYear
2013
fDate
Jan. 2013
Firstpage
199
Lastpage
212
Abstract
The proposed perturbation on-time technique suppresses total harmonic distortion (THD) and, thus, improves the power factor in the power factor correction (PFC) controller. Besides, the adaptive control of the minimum off time by the proposed inhibit time control can improve efficiency even at low ac input voltage. Therefore, highly integrated PFC converter fabricated in the TSMC 800-V ultrahigh voltage process can achieve low THD of 6%, high PF of 99%, and high efficiency of 95% at the output power of 90 W.
Keywords
harmonic distortion; harmonics suppression; power factor correction; PFC controller; POT technique; THD suppression; TSMC ultrahigh voltage process; adaptive control; efficiency 95 percent; highly- integrated PFC converter; inhibit time control; perturbation on-time technique; power 90 W; power factor correction controller; total harmonic distortion; voltage 800 V; Capacitance; Capacitors; Inductors; MOSFET circuits; Reactive power; Voltage control; Windings; Inhibit time (IT) control; nonnegative-voltage zero current detector (NNV-ZCD); perturbation on time (POT); power factor correction (PFC); ultrahigh voltage (UHV);
fLanguage
English
Journal_Title
Power Electronics, IEEE Transactions on
Publisher
ieee
ISSN
0885-8993
Type
jour
DOI
10.1109/TPEL.2012.2195333
Filename
6187737
Link To Document