• DocumentCode
    9457
  • Title

    Perturbation On-Time (POT) Technique in Power Factor Correction (PFC) Controller for Low Total Harmonic Distortion and High Power Factor

  • Author

    Tsai, Jen-Chieh ; Chen, Chi-Lin ; Chen, Yi-Ting ; Ni, Chia-Lung ; Chen, Chun-Yen ; Chen, Ke-Horng

  • Author_Institution
    Inst. of Electr. Control Eng., Nat. Chiao Tung Univ., Hsinchu, Taiwan
  • Volume
    28
  • Issue
    1
  • fYear
    2013
  • fDate
    Jan. 2013
  • Firstpage
    199
  • Lastpage
    212
  • Abstract
    The proposed perturbation on-time technique suppresses total harmonic distortion (THD) and, thus, improves the power factor in the power factor correction (PFC) controller. Besides, the adaptive control of the minimum off time by the proposed inhibit time control can improve efficiency even at low ac input voltage. Therefore, highly integrated PFC converter fabricated in the TSMC 800-V ultrahigh voltage process can achieve low THD of 6%, high PF of 99%, and high efficiency of 95% at the output power of 90 W.
  • Keywords
    harmonic distortion; harmonics suppression; power factor correction; PFC controller; POT technique; THD suppression; TSMC ultrahigh voltage process; adaptive control; efficiency 95 percent; highly- integrated PFC converter; inhibit time control; perturbation on-time technique; power 90 W; power factor correction controller; total harmonic distortion; voltage 800 V; Capacitance; Capacitors; Inductors; MOSFET circuits; Reactive power; Voltage control; Windings; Inhibit time (IT) control; nonnegative-voltage zero current detector (NNV-ZCD); perturbation on time (POT); power factor correction (PFC); ultrahigh voltage (UHV);
  • fLanguage
    English
  • Journal_Title
    Power Electronics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-8993
  • Type

    jour

  • DOI
    10.1109/TPEL.2012.2195333
  • Filename
    6187737