Title :
A low-cost microsystem for noninvasive uroflowmetry
Author :
Viarani, Nicola ; Massari, Nicola ; Gottardi, Massimo ; Simoni, Andrea ; Margesin, Benno ; Faes, Alessandro ; Decarli, Massimiliano ; Guarnieri, Vittorio
Author_Institution :
Center for Sci. & Technol. Res., Trento
fDate :
6/1/2006 12:00:00 AM
Abstract :
A microsystem composed of a micromachined resistive flow sensor and a signal conditioning CMOS IC is proposed for biomedical applications. The device can be adapted to noninvasively monitor urinary dysfunctions in male patients. The flow sensor, thermally simulated with ANSYS, is based on the hot-film principle: A thin film of gold laid on a suspended micromachined silicon membrane is heated while the fluid under test flows through the duct mounted above the membrane. The flow rate is sensed by measuring the temperature difference between two of the four polysilicon temperature sensors realized on the membrane. Simulations of the flow sensor with flow rates within 0.1-18 ml/s evidence a maximum temperature difference of 20degC between the temperature sensors. Characterization of the fabricated flow sensor shows temperature coefficient of resistance (TCR) values of -1930 ppm/degC for the polysilicon resistors, i.e., a resistance variation of about 4% at high flow rates. The CMOS readout designed for the flow sensor is a resistive bridge-to-duty cycle converter based on a relaxation oscillator. The digital output of the circuit is duty-cycle modulated by the change in resistance of the flow sensor´s elements. Experimental tests on the CMOS interface, conducted with a setup of 1% precision resistors, report a maximum nonlinearity below 0.9% and a resolution of 7 bits over the full range of 4% resistance variation. The CMOS integrated readout circuit, provided with a digital output, allows simple signal interfacing towards any standard PC for periodical data transfer and storage
Keywords :
CMOS integrated circuits; biomedical measurement; flow sensors; flowmeters; micromachining; readout electronics; signal processing equipment; ANSYS; CMOS integrated readout circuit; biomedical applications; flow rate; gold; hot film principle; micromachining; microsystem; noninvasive uroflowmetry; resistive flow sensor; signal conditioning CMOS IC; silicon membrane; temperature sensors; urinary dysfunctions monitoring; Application specific integrated circuits; Biomembranes; Biosensors; CMOS integrated circuits; Immune system; Patient monitoring; Resistors; Sensor phenomena and characterization; Temperature sensors; Thin film sensors; Bridge-to-duty cycle converter; micromachined resistive flow sensor; microsystem; noninvasive uroflowmetry; relaxation oscillator;
Journal_Title :
Instrumentation and Measurement, IEEE Transactions on
DOI :
10.1109/TIM.2006.864242