DocumentCode :
946996
Title :
Intraoperative Laparoscope Augmentation for Port Placement and Resection Planning in Minimally Invasive Liver Resection
Author :
Feuerstein, Marco ; Mussack, Thomas ; Heining, Sandro M. ; Navab, Nassir
Author_Institution :
Nagoya Univ., Nagoya
Volume :
27
Issue :
3
fYear :
2008
fDate :
3/1/2008 12:00:00 AM
Firstpage :
355
Lastpage :
369
Abstract :
In recent years, an increasing number of liver tumor indications were treated by minimally invasive laparoscopic resection. Besides the restricted view, two major intraoperative issues in laparoscopic liver resection are the optimal planning of ports as well as the enhanced visualization of (hidden) vessels, which supply the tumorous liver segment and thus need to be divided (e.g., clipped) prior to the resection. We propose an intuitive and precise method to plan the placement of ports. Pre operatively, self-adhesive fiducials are affixed to the patient´s skin and a computed tomography (CT) data set is acquired while contrasting the liver vessels. Immediately prior to the intervention, the laparoscope is moved around these fiducials, which are automatically reconstructed to register the patient to its preoperative imaging data set. This enables the simulation of a camera flight through the patient´s interior along the laparoscope´s or instruments´ axes to easily validate potential ports. Intraoperatively, surgeons need to update their surgical planning based on actual patient data after organ deformations mainly caused by application of carbon dioxide pneumoperitoneum. Therefore, preoperative imaging data can hardly be used. Instead, we propose to use an optically tracked mobile C-arm providing cone-beam CT imaging capability intraoperatively. After patient positioning, port placement, and carbon dioxide insufflation, the liver vessels are contrasted and a 3-D volume is reconstructed during patient exhalation. Without any further need for patient registration, the reconstructed volume can be directly augmented on the live laparoscope video, since prior calibration enables both the volume and the laparoscope to be positioned and oriented in the tracking coordinate frame. The augmentation provides the surgeon with advanced visual aid for the localization of veins, arteries, and bile ducts to be divided or sealed.
Keywords :
computerised tomography; liver; surgery; tumours; 3D volume reconstruction; arteries; bile ducts; carbon dioxide pneumoperitoneum; computed tomography; intraoperative laparoscope augmentation; liver tumor; minimally invasive liver resection; port placement; resection planning; surgical planning; veins; Augmented Reality Visualization; Augmented reality visualization; Image-Guided Surgery; Laparoscopic Surgery; Port Placement; image-guided surgery; laparoscopic surgery; port placement; Animals; Equipment Design; Equipment Failure Analysis; Hepatectomy; Humans; Laparoscopes; Preoperative Care; Surgery, Computer-Assisted; Surgical Procedures, Minimally Invasive; Swine; Tomography, X-Ray Computed; User-Computer Interface;
fLanguage :
English
Journal_Title :
Medical Imaging, IEEE Transactions on
Publisher :
ieee
ISSN :
0278-0062
Type :
jour
DOI :
10.1109/TMI.2007.907327
Filename :
4359067
Link To Document :
بازگشت