Characterization of single and multiple scatter from matter and activity distributions outside the FOV in 3-D PET
Author :
Laymon, C.M. ; Harrison, R.L. ; Kohlmyer, S.G. ; Miyaoka, R.S. ; Lewellen, T.K.
Author_Institution :
Univ. of Washington, Seattle, WA, USA
Volume :
51
Issue :
1
fYear :
2004
Firstpage :
10
Lastpage :
15
Abstract :
Operation of PET in 3-D mode, without internal septa results in increased sensitivity but at the cost of increased scatter fraction. Significant amounts of scattered events in 3-D PET either originate from activity outside the FOV (OFOV) or scatter from matter outside the FOV, complicating scatter correction methods. We performed 3-D PET simulations with scanner geometry based on the GE Advance with several phantom geometries designed to characterize all scatter with particular attention to that from outside the FOV. Scatter from OFOV matter was deduced by performing simulations with matter and activity within the FOV only (short phantom). Studies were repeated with phantoms with identical characteristics inside the FOV but with additional OFOV material (long phantom) but no activity outside the FOV. The incremental effect of OFOV activity was then determined by repeating the long phantom studies with additional activity. Scatter was also classified as single or multiple. In summary, the data allow extraction of yields from unscattered and all types of scattered events. The effect of source position, both within and external to the FOV, on scatter was determined by performing a series of simulations with point sources and techniques similar to those described above. The effect of energy discriminator setting (with BGO detectors) was also studied and data sets were generated for five settings from 300 to 425 keV. Using a Zubal phantom with the lungs and heart in the FOV and the abdomen outside the FOV and with a 300 keV discriminator, we find a total scatter fraction of 57%. Of the total scatter, 7.4% comes from OFOV matter, and 24% from OFOV activity. If the discriminator is increased to 425 keV the scatter fraction drops to 36%. OFOV scatter, particularly from OFOV activity, becomes relatively less important with the OFOV matter contribution dropping to 5.3% and OFOV activity contribution to 17%. Additionally, the spatial distributions of scatter from external matter and external activity were found to be different.
Keywords :
Monte Carlo methods; cardiology; lung; medical image processing; phantoms; positron emission tomography; scattering; solid scintillation detectors; 3-D PET simulations; BGO detectors; OFOV; Zubal phantom; abdomen; activity contribution; activity outside field of view; biomedical image processing; biomedical imaging; external activity; heart; lungs; matter distribution; phantom geometries; positron emission tomography; scanner geometry; scatter correction methods; source position; spatial distributions; total scatter fraction; Costs; Data mining; Detectors; Geometry; Heart; Imaging phantoms; Lungs; Positron emission tomography; Scattering; Solid modeling;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.2004.823340
Filename :
1282053
Link To Document :
بازگشت