Title :
A comparison of planar versus volumetric numerical observers for detection task performance in whole-body PET imaging
Author :
Kim, Jae-Seung ; Kinahan, Paul E. ; Lartizien, Carole ; Comtat, Claude ; Lewellen, Thomas K.
Author_Institution :
Univ. of Washington, Seattle, WA, USA
Abstract :
The goal of this project is to determine if there is a difference between planar and volumetric numerical observers. The motivation comes from the use of a volumetric (3-D) display of image data (i.e., three orthogonal views through a volume image) to assess whole-body PET images in most, if not all, clinical PET centers. Studies of correlations between numerical observers and human observers (e.g., using receiver operating characteristic (ROC) detection analysis), however, typically use a planar (2-D) display and analysis methodology. In particular, planar implementations of the nonprewhitening matched filter (NPWMF) and the channelized Hotelling observer (CHO) have been extensively investigated as surrogates for measuring human detection task performance. To determine if there is a difference between planar and volumetric numerical observers, we analyzed the behavior of 2-D and 3-D implementations of the NPWMF and CHO numerical observers with multiple realizations of images with noise properties similar to those of whole-body PET oncology imaging. The results indicate that there is a significant increase in SNR or detectability of volumetric numerical observers relative to planar observers. This implies that volumetric and planar numerical observers may have different strengths of correlation with human observer performance, and that these correlations should be determined prior to using numerical observers to optimize algorithm or protocol performance for whole-body PET imaging. When axial smoothing is applied, however, to impose isotropic target resolution or to simulate fully 3-D PET data, the detectabilities of planar numerical observers are increased and the differences between planar and volumetric numerical observers become less significant.
Keywords :
biomedical imaging; cancer; positron emission tomography; sensitivity analysis; task analysis; tumours; SNR; channelized Hotelhng observer; clinical PET centers; human detection task performance; image data; isotropic target resolution; noise properties; nonprewhitening matched filter; planar 2-D display; planar numerical observers; receiver operating characteristic detection analysis; volumetric 3D display; volumetric numerical observer; whole-body PET oncology imaging; Anthropometry; Displays; Humans; Image analysis; Matched filters; Oncology; Particle measurements; Protocols; Signal to noise ratio; Whole-body PET;
Journal_Title :
Nuclear Science, IEEE Transactions on
DOI :
10.1109/TNS.2004.823329