• DocumentCode
    947849
  • Title

    Calibration of 16-term error model (microwave measurement)

  • Author

    Silvonen, K.J.

  • Author_Institution
    Helsinki Univ. of Technol., Espoo, Finland
  • Volume
    29
  • Issue
    17
  • fYear
    1993
  • Firstpage
    1544
  • Lastpage
    1545
  • Abstract
    Based on numerical simulations it is pointed out that five calibration measurements are needed to exactly calibrate the 16-parameter error model (for measurements of microwave circuits). Possible combinations of calibration standards are studied. The nonsingular combinations are listed in a Table.<>
  • Keywords
    calibration; measurement errors; microwave circuits; microwave measurement; 16-term error model; calibration measurements; calibration standards; microwave circuits; microwave measurement; numerical simulations; sixteen parameter error model;
  • fLanguage
    English
  • Journal_Title
    Electronics Letters
  • Publisher
    iet
  • ISSN
    0013-5194
  • Type

    jour

  • DOI
    10.1049/el:19931029
  • Filename