DocumentCode
947849
Title
Calibration of 16-term error model (microwave measurement)
Author
Silvonen, K.J.
Author_Institution
Helsinki Univ. of Technol., Espoo, Finland
Volume
29
Issue
17
fYear
1993
Firstpage
1544
Lastpage
1545
Abstract
Based on numerical simulations it is pointed out that five calibration measurements are needed to exactly calibrate the 16-parameter error model (for measurements of microwave circuits). Possible combinations of calibration standards are studied. The nonsingular combinations are listed in a Table.<>
Keywords
calibration; measurement errors; microwave circuits; microwave measurement; 16-term error model; calibration measurements; calibration standards; microwave circuits; microwave measurement; numerical simulations; sixteen parameter error model;
fLanguage
English
Journal_Title
Electronics Letters
Publisher
iet
ISSN
0013-5194
Type
jour
DOI
10.1049/el:19931029
Filename
234381
Link To Document