    Evaluation of maximum-likelihood position estimation with Poisson and Gaussian noise models in a small gamma camera

  • Author

    Chung, Yong Hyun ; Choi, Yong ; Song, Tae Yong ; Jung, Jin Ho ; Cho, Gyuseong ; Choe, Yearn Seong ; Lee, Kyung-Han ; Kim, Sang Eun ; Kim, Byung-Tae

  • Author_Institution
    Dept. of Nucl. Med., Sungkyunkwan Univ. Sch. of Med., Seoul, South Korea
  • Volume
    51
  • Issue
    1
  • fYear
    2004
  • Firstpage
    101
  • Lastpage
    104
  • Abstract
    It has been reported that maximum-likelihood position estimation (MLPE) algorithms offer advantages of improved spatial resolution and linearity over conventional Anger algorithm in gamma cameras. While the fluctuation of photon measurements is more accurately described by Poisson than Gaussian distribution model, the likelihood function of a scintillation event assumed to be Gaussian could be more easily implemented and might provide more consistent outcomes than Poisson-based MLPE. The purpose of this study is to evaluate the performances of the noise models, Poisson and Gaussian, in MLPE for the localization of photons in a small gamma camera (SGC) using NaI(Tl) plate and PSPMT. The SGC consisted of a single NaI(Tl) crystal, 10 cm in diameter and 6 mm thick, optically coupled to a PSPMT (Hamamatsu R3292-07). The PSPMT was read out using a resistive charge divider, which multiplexes 28(X) by 28(Y) cross wire anodes into four channels. Poisson and Gaussian-based MLPE methods have been implemented using experimentally measured detector response functions (DRF). The averaged intrinsic spatial resolutions were 3.14, 3.09, and 2.88 mm, the integral uniformities were 15.3%, 12.3%, and 11.4%, and the averaged linearities were 0.75, 0.33, and 0.22 mm for Anger logic, Poisson, and Gaussian-based MLPE, respectively. MLPEs considerably improved linearity and uniformity compared to Anger logic. Gaussian-based MLPE, which is easy to implement, allowed to obtain better linearity and uniformity performances than the Poisson-based MLPE.
  • Keywords
    Gaussian distribution; Poisson distribution; fluctuations; gamma-ray apparatus; gamma-ray detection; maximum likelihood estimation; photomultipliers; position sensitive particle detectors; solid scintillation detectors; 10 cm; 6 mm; Anger logic; DRF; Gaussian noise model; MLPE algorithms; NaI(Tl) plate; PSPMT; Poisson noise model; SGC; averaged intrinsic spatial resolutions; conventional Anger algorithm; cross wire anodes; detector response functions; fluctuation; integral uniformities; linearity; maximum-likelihood position estimation; photon localization; photon measurements; position sensitive photomultiplier tubes; resistive charge divider; scintillation event; single NaI(Tl) crystal; small gamma camera; uniformity; Cameras; Fluctuations; Gaussian noise; Gaussian processes; Linearity; Logic; Maximum likelihood detection; Maximum likelihood estimation; Optical noise; Spatial resolution;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.2003.823053
  • Filename
    1282069