• DocumentCode
    949237
  • Title

    Resolved component indicator based on digitally generated quadrature references

  • Author

    Izatt, T.G. ; Ball, E.

  • Author_Institution
    Preston Polytechnic, School of Electrical & Electronic Engineering, Preston, UK
  • Volume
    15
  • Issue
    3
  • fYear
    1979
  • Firstpage
    83
  • Lastpage
    84
  • Abstract
    A resolved component indicator based on fixed-frequency quadrature square-wave reference signals has been developed, which has the property of rejecting unwanted noise and harmonics in the output of the system under test and which indicates the amplitude to better than 2% and phase angle to within 0.5° over the frequency range 10 Hz to 10 kHz.
  • Keywords
    digital instrumentation; frequency response; gain measurement; digitally generated quadrature references; resolved component indicator;
  • fLanguage
    English
  • Journal_Title
    Electronics Letters
  • Publisher
    iet
  • ISSN
    0013-5194
  • Type

    jour

  • DOI
    10.1049/el:19790061
  • Filename
    4242978