DocumentCode :
949237
Title :
Resolved component indicator based on digitally generated quadrature references
Author :
Izatt, T.G. ; Ball, E.
Author_Institution :
Preston Polytechnic, School of Electrical & Electronic Engineering, Preston, UK
Volume :
15
Issue :
3
fYear :
1979
Firstpage :
83
Lastpage :
84
Abstract :
A resolved component indicator based on fixed-frequency quadrature square-wave reference signals has been developed, which has the property of rejecting unwanted noise and harmonics in the output of the system under test and which indicates the amplitude to better than 2% and phase angle to within 0.5° over the frequency range 10 Hz to 10 kHz.
Keywords :
digital instrumentation; frequency response; gain measurement; digitally generated quadrature references; resolved component indicator;
fLanguage :
English
Journal_Title :
Electronics Letters
Publisher :
iet
ISSN :
0013-5194
Type :
jour
DOI :
10.1049/el:19790061
Filename :
4242978