DocumentCode :
949324
Title :
Resolution in large rectangular NaI(Tl) detectors: a study
Author :
Ramana, P. Venkata ; Srinivas, G.
Author_Institution :
Dept. of Atomic Energy, Hyderabad, India
Volume :
40
Issue :
5
fYear :
1993
fDate :
10/1/1993 12:00:00 AM
Firstpage :
1325
Lastpage :
1328
Abstract :
Experiments were carried out for studying the resolution of 4-in (10-cm)×4-in (10-cm)×16-in (40-cm) NaI(Tl) detectors used in high-sensitivity airborne gamma-ray spectrometric surveys. Change of resolution with source-detector geometry emphasized the inadequacy of existing specifications for resolution in explaining the detector response. An additional specification for resolution measurement, namely, overall resolution, is proposed. Measurement and applications of overall resolution of the detector are discussed
Keywords :
cosmic ray apparatus; gamma-ray detection and measurement; scintillation counters; sodium compounds; thallium; NaI:Tl; detector response; high-sensitivity airborne gamma-ray spectrometric surveys; resolution measurement; source-detector geometry; Crystals; Energy resolution; Gamma ray detection; Gamma ray detectors; Helium; Preamplifiers; Radiometry; Sensor arrays; Spectroscopy; Voltage;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/23.234544
Filename :
234544
Link To Document :