Title :
Mapping of the near-field pattern in simulated biological tissues
Author :
Gajda, G. ; Stuchly, M.A. ; Stuchly, S.S.
Author_Institution :
University of Ottawa, Department of Electrical Engineering, Ottawa, Canada
Abstract :
A simple system for mapping the electric-field pattern created in simulated biological tissue by a microwave applicator is described. The system employs a short probe sensitive to the E-field in one direction, which is driven along a sekcted path by the X-scan of an X-Y recorder while the intensity of the field measured by a diode detector is recorded simultaneously along the Y-coordinate of the recorder. Liquid dielectrics are used to simulate electric properties of the biological tissues. The system provides a viable complementary or alternative technique to the thermographic-camera method in evaluating the performance of microwave applicators for local hyperthermia.
Keywords :
biological effects of microwaves; electric field measurement; microwave measurement; electric field pattern mapping; mapping system; microwave diathermy applicators; microwave fields; near field pattern; simulated biological tissues;
Journal_Title :
Electronics Letters
DOI :
10.1049/el:19790088