DocumentCode
953551
Title
The use of Flourocarbon Gases to Prevent Arc-Over in DC Capacitors
Author
Loescher, Douglas H.
Author_Institution
Sandia Laboratories
Volume
11
Issue
2
fYear
1975
fDate
6/1/1975 12:00:00 AM
Firstpage
108
Lastpage
110
Abstract
The use of Fr-14 (CF4 ) and Fr-116 (C2 F6 ) to increase the margin arc-over voltage in dry Mylar energy storage capacitors is investigated. It is found that pressurization of capacitors with Fr-14 results in a small increase in arc-over voltage. However, pressurization with Fr-116 results in arcover voltages 1.5 to 2.5 times larger than obtained in air.
Keywords
Dielectric breakdown; Thin-film capacitors; Aluminum; Breakdown voltage; Capacitors; Dielectric breakdown; Dielectric films; Engine cylinders; Gases; Temperature; Testing; Voltage control;