Title :
The use of Flourocarbon Gases to Prevent Arc-Over in DC Capacitors
Author :
Loescher, Douglas H.
Author_Institution :
Sandia Laboratories
fDate :
6/1/1975 12:00:00 AM
Abstract :
The use of Fr-14 (CF4) and Fr-116 (C2F6) to increase the margin arc-over voltage in dry Mylar energy storage capacitors is investigated. It is found that pressurization of capacitors with Fr-14 results in a small increase in arc-over voltage. However, pressurization with Fr-116 results in arcover voltages 1.5 to 2.5 times larger than obtained in air.
Keywords :
Dielectric breakdown; Thin-film capacitors; Aluminum; Breakdown voltage; Capacitors; Dielectric breakdown; Dielectric films; Engine cylinders; Gases; Temperature; Testing; Voltage control;
Journal_Title :
Parts, Hybrids, and Packaging, IEEE Transactions on
DOI :
10.1109/TPHP.1975.1135046