• DocumentCode
    953551
  • Title

    The use of Flourocarbon Gases to Prevent Arc-Over in DC Capacitors

  • Author

    Loescher, Douglas H.

  • Author_Institution
    Sandia Laboratories
  • Volume
    11
  • Issue
    2
  • fYear
    1975
  • fDate
    6/1/1975 12:00:00 AM
  • Firstpage
    108
  • Lastpage
    110
  • Abstract
    The use of Fr-14 (CF4) and Fr-116 (C2F6) to increase the margin arc-over voltage in dry Mylar energy storage capacitors is investigated. It is found that pressurization of capacitors with Fr-14 results in a small increase in arc-over voltage. However, pressurization with Fr-116 results in arcover voltages 1.5 to 2.5 times larger than obtained in air.
  • Keywords
    Dielectric breakdown; Thin-film capacitors; Aluminum; Breakdown voltage; Capacitors; Dielectric breakdown; Dielectric films; Engine cylinders; Gases; Temperature; Testing; Voltage control;
  • fLanguage
    English
  • Journal_Title
    Parts, Hybrids, and Packaging, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0361-1000
  • Type

    jour

  • DOI
    10.1109/TPHP.1975.1135046
  • Filename
    1135046