DocumentCode
955056
Title
Performance of New Copper Based Metallization Systems in an 85°C 80-Percent RH Cl2 Contaminated Environment
Author
Sbar, Neil L. ; Feinstein, Leonard G.
Author_Institution
Bell Telephone Lab.,Allentown,PA
Volume
13
Issue
3
fYear
1977
fDate
9/1/1977 12:00:00 AM
Firstpage
208
Lastpage
218
Abstract
The performance of TPCNA (Ti-Pd-Cu-Ni-Au) and TCN+A (Ti-CuoNi+Au in selected areas only) meta!lizations in 85°C, 80-percent RH, with 0.5 to 1.8 ppm Cl2 was compared with that of the standard TPA (Ti-Pd-Au) metallization. Encapsulated (RTV silicone rubber) and unencapsulated triple track conductor test specimens were used. Electrolytic corrosion was studied by biasing the specimens in the high humidity corrosive environment and measuring in situ leakage currents as a function of time. For the unencapsulated specimens, leakage currents increased and all samples failed by 600 h. The failure rates for TPCNA and TCN+A samples due to the formation of Cu and Ni dendrites between oppositely biased conductors were the same as for TPA which had Au and Pd dentrites. None of the encapsulated samples showed dendrite growth after ~ 1000 h. Unencapsulated TPCNA and TCN+A were less resistant to galvanic corrosion in the moist Cl2 contaminated environment than were the TPA specimens. TCN+A failed first by Ti-Cu delamination and later by delamination of the Au due to corrosive oxidation of the underlying Ni. This latter failure mode was predominant for TPCNA. TPA conductors eventually failed at Ti-Pd interfaces. At 85°C, 80-percent RH, 1.6 ppm C!2, unencapsulated TCN+A degraded at the Ti-Cu interface ~10 times faster than unencapsulated TPA at the Ti-Pd interface. The corrosion product found on unencapsulated TPCNA and TCN+A and on Cu-NiAu external leads was identified as Cu, NiCl2 . 3 [Cu, Ni(OH)2 ]. The encapsulant was extremely effective in retarding galvanic corrosion. For encapsulated TCN+A and TPCNA, eventual bond failures were the result of penetration of the corrosive environment under the edges of the encapsulant. For TCN+A, encapsulation retarded the time to failure by a factor of >10. The relative resistance to galvanic corrosion in moist Cl2 may be ranked TPA > TPCNA > TCN+A.
Keywords
Component reliability; Copper alloys/compounds; Corrosion; Gold alloys/compounds; Metallization; Nickel alloys/compounds; Palladium alloys/compounds; Titanium alloys/compounds; Conductors; Copper; Corrosion; Delamination; Galvanizing; Gold; Leakage current; Metallization; Rubber; Testing;
fLanguage
English
Journal_Title
Parts, Hybrids, and Packaging, IEEE Transactions on
Publisher
ieee
ISSN
0361-1000
Type
jour
DOI
10.1109/TPHP.1977.1135194
Filename
1135194
Link To Document