Title :
Use of superconducting self-correcting harmonic coils for pulsed superconducting dipole or multipole magnets
Author :
Dael, A. ; Kircher, F. ; Perot, J.
Author_Institution :
Laboratoire de ĺAccélérateur Linéaire, ORSAY (France)
fDate :
3/1/1975 12:00:00 AM
Abstract :
Thanks to the zero resistance of a superconducting wire, an induced current in a closed superconducting circuit is continuously exactly opposed to its cause. This phenomenon has been applied to the correction of the field harmonics of a pulsed magnet by putting short-circuited superconducting coils of particular symmetry in the useful aperture of the magnet. After a recall of the choices to be done for the main characteristics of such devices [1], the construction of two correcting coils (quadrupole and sextupole) is described. Experimental results about magnetic efficiency and time behaviour are given; they are quite encouraging since the field harmonicshave been reduced by one or two orders of magnitude.
Keywords :
Superconducting magnets; Apertures; Circuits; Couplings; Inductance; Magnetic fields; Magnetic flux; Superconducting coils; Superconducting magnets; Wire; Wounds;
Journal_Title :
Magnetics, IEEE Transactions on
DOI :
10.1109/TMAG.1975.1058708