Title :
On using a sense wire to quantitate the magnetic flux leakage through an aperture in an electromagnetic shield
Author :
Taylor, C.D. ; Prather, W.D. ; Herrmann, Carl C.
Author_Institution :
Dept. of Electr. & Comput. Eng., Ohio Univ., Athens, OH
fDate :
11/1/1989 12:00:00 AM
Abstract :
A formulation is developed for determining the sensitivity of positioning a sense wire behind an aperture in an electromagnetic shield to quantitate the flux leakage through the aperture. Both hardened and unhardened circular apertures are considered. Comparisons with measured data are made to verify the analysis
Keywords :
magnetic leakage; magnetic shielding; circular apertures; electromagnetic shield; hardened aperture; magnetic flux leakage; sense wire; unhardened aperture; Apertures; Electromagnetic measurements; Electromagnetic shielding; Magnetic analysis; Magnetic flux leakage; Wire;
Journal_Title :
Electromagnetic Compatibility, IEEE Transactions on